Skip to content

Spec decoder

AHAM vs Saturation vs DOE 65°F Pint Converter

The same dehumidifier can be sold as “55 pints,” “120 pints,” or “34 pints” depending on the test condition. Enter any advertised rating and its standard to see the approximate equivalent in all three.

Advertised rating

PPD
Test standard on the box / listing

Equivalent capacity

AHAM 80°F / 60%

55.8PPD

Use this to size and compare

Saturation 90°F / 90%

120.0PPD

DOE 65°F / 60%

34.9PPD

Approximate — real ratios vary by model (see the table below).

Crawl space units near 56 PPD (AHAM)

Best value (gravity)

AlorAir Sentinel HD55S

Best value (gravity)

AHAM capacity
55 PPD
Saturation (published)
120 PPD
Mfr. coverage
up to 1,300 sq ft
Airflow
130 CFM
  • Gravity drain only (no internal pump)
  • Min. operating temp 33.8°F (auto-defrost)
  • Energy factor 2.4 L/kWh
  • 6-year limited (first 2 years full)

$506 approx., checked 2026-11-28 (aloraircrawlspace.com sale price)

Best value (pump)

AlorAir Sentinel HDi65S

Best value (pump)

AHAM capacity
55 PPD
Saturation (published)
120 PPD
Mfr. coverage
up to 1,300 sq ft
Airflow
130 CFM
  • Built-in pump (19.6 ft drain height) or gravity
  • Min. operating temp 33.8°F (auto-defrost)
  • Energy factor 2.4 L/kWh
  • 6-year limited (first 2 years full)

$635 approx., checked 2026-11-28 (aloraircrawlspace.com sale price, Wi-Fi version)

Mid-size (pump)

AlorAir Galaxy 60P

Mid-size (pump)

AHAM capacity
60 PPD
Saturation (published)
145 PPD
Mfr. coverage
up to 1,800 sq ft
Airflow
165 CFM
  • Built-in pump or gravity
  • Min. operating temp 37.4°F (auto-defrost)
  • Energy factor 2.4 L/kWh
  • 6-year limited (first 2 years full)

$638 approx., checked 2026-11-28 (aloraircrawlspace.com sale price)

Engineering methodology & formula

The converter uses two rule-of-thumb factors. They are approximations for comparison shopping, not results of a standardized test.

saturation ≈ AHAM × 2.15
DOE_65F    ≈ AHAM × 0.625
reverse:   AHAM = saturation ÷ 2.15  |  AHAM = DOE_65F ÷ 0.625

Reality check against published data: saturation ÷ AHAM ratios on the units we list range from 1.96 to 2.42. Santa Fe publishes 43.7 PPD at 65°F/60% RH for the 70 PPD (AHAM) Compact70, a ratio of 0.62 — close to the 0.625 factor.

Published ratings vs the rule of thumb

ModelAHAM (published)Saturation (published)Published ratioRule-of-thumb saturation
AlorAir Sentinel HD35P35 PPD70 PPD2.0075 PPD
AlorAir Sentinel HD55S55 PPD120 PPD2.18118 PPD
AlorAir Sentinel HDi65S55 PPD120 PPD2.18118 PPD
AlorAir Galaxy 60P60 PPD145 PPD2.42129 PPD
Santa Fe Compact7070 PPDNot published—151 PPD
AprilAire E08080 PPDNot published—172 PPD
AlorAir Galaxy 85P85 PPD180 PPD2.12183 PPD
AlorAir Sentinel HD9090 PPD198 PPD2.20194 PPD
AlorAir Sentinel HDi9090 PPD198 PPD2.20194 PPD
AlorAir Sentinel HDi100100 PPD220 PPD2.20215 PPD
AlorAir Sentinel HDi120120 PPD235 PPD1.96258 PPD
AprilAire E130130 PPDNot published—280 PPD

Why three different pint ratings exist

Warm, humid air holds more water and gives a dehumidifier’s coil more to condense, so the same machine removes more pints when the test room is hotter and wetter. AHAM conditions (80°F, 60% RH) were the long-standing US reference and are still how crawl space and whole-house units are usually rated. Saturation figures (about 90°F, 90% RH) appear on many commercial and crawl space listings because they produce the biggest number. The 2019 DOE procedure for portable dehumidifiers moved to 65°F and 60% RH, closer to a cool basement, which made the familiar “70-pint” portables re-label as about 50 pints.

Watch for mixed standards in comparisons

A “120-pint” crawl space unit at saturation and a “50-pint” portable at DOE 65°F can be closer in real capacity than the labels suggest — or much further apart. Convert both to AHAM before comparing, then look at airflow, drainage, and minimum operating temperature. Our sizing calculator outputs its recommendation in AHAM pints for this reason.

Frequently asked questions

What is the difference between AHAM and saturation pint ratings?

AHAM ratings are measured at 80°F and 60% relative humidity. Saturation ratings are measured at about 90°F and 90% RH, where air holds far more water, so the same unit removes roughly twice as many pints. Crawl space sizing guidance is normally written in AHAM pints.

What is the DOE 65°F rating?

Since 2019 the US DOE test for portable dehumidifiers uses 65°F and 60% RH, which produces lower pint numbers than the older 80°F AHAM condition. A unit sold as “50 pint (2019 DOE)” is not comparable to a crawl space unit rated in AHAM pints without conversion.

How accurate are the conversion factors?

They are rule-of-thumb averages. Published ratios vary by model: on the units in our database, the published saturation-to-AHAM ratio ranges from about 1.96 to 2.42, and Santa Fe publishes 43.7 PPD at 65°F for a 70 PPD AHAM unit (0.62). Use the converter for apples-to-apples comparison, not as a lab result.

Which rating should I use to compare two dehumidifiers?

Convert both to the same standard — ideally AHAM — before comparing. Then check airflow (CFM), drainage type, minimum operating temperature, and energy factor.